Monday, 24 March 2014

Cost blowout... and again another...

It's been a while since we have updated where the house build is up to.
Since last time, there was an initial period of waiting... and waiting... for the building quote to come in.
Then there was a period of extreme horror when the quote did arrive - and we saw it was nearly $250,000 over our budget.
After that there was a small glimmer of hope that, if we changed some of the materials from concrete to more lightweight products, we may be able to bring the budget back on track.
That glimmer was rapidly snuffed when the second quote came in, still about $150,000 over our budget (and not including the cost of the Epic Driveway, nor the fixtures and fittings we have chosen).
What caused this?
Essentially, the requirement to allow for the turning circle of a fire truck on the building site meant that the house was moved about 8 - 9 metres further down the hill. This positioned the house on a much steeper part of the block. As a result, we no longer could have the slab on ground, rather we would have to build a suspended concrete slab, and the Super Duper Footings that go along with that.
Unfortunately, even lighter building materials didn't fix the budget blowout - and these materials would fundamentally alter the aesthetic of the house.
This left us having a teleconference with Neal-the-architect over the sad situation we found ourselves in.
Basically, there were two options we could consider:

Option 1: Keep the building on the steeper part of the block, use lighter materials, but reduce the scope by removing the mezzanine, greenhouse, carport and breezeway and relocating Andy’s studio underneath the living room (not much house left after that)

Option 2: Investigate moving the building back to its original position and hopefully having the block work and slab on ground; and hopefully have this back in budget as estimated back in June 2013

After mulling over these options, there were some immediate issues springing to mind:

Option 1:
  • At it’s current size and with the lighter building materials, this didn't appear to be a financially viable option. Were something to happen in the near future which forced us to have to sell, we would never obtain a selling price which would cover the cost of the build. And reducing the size of the building to lower build costs, wouldn’t resolve this, but potentially make it worse
  • Of additional concern, while we plan to personally fund part of the build, we will require finance for the remainder – banks are notoriously cautious creatures and we may encounter difficulties in obtaining finance if the bank cannot see the value in the build.
  • Comparable insulation amounts may be able to be achieved with lightweight materials, but we lose the thermal mass by removing the concrete
Option 2:
  • The bushfire consultant previously advised that using the neighbour's driveway as a turning point for the fire truck would be too far from the site
  • We don’t have the neighbour's permission (nor actually know who that neighbour is) to use their driveway
  • We are presuming that the neighbour’s driveway would need to be upgraded to allow the fire truck to use it to turn – and this may be a cost that we would have to bear
  • What other fees would be involved in relocating back to the original site? (engineering? Council? architect? surveyor?) What is the financial impact to us of these additional fees?
  • Is there even any likelihood that, having done all of the above, the build would come in on budget?
And that is pretty much where we were up to as of last week.
After 2 years of planning, and considerable financial outlay, we have 2 house designs, neither of which we can afford to build.
Neal-the-architect is making enquiries in relation to Option 2.
But the Android and Viktoria are in agreement... if we cannot proceed with Option 2, then we have no other choice but to notch the whole thing up to experience and count our losses.
Sincerely hoping that this week brings better news.
V&A

Sunday, 16 February 2014

"Curiouser and curiouser", said Alice...

You put the mezzanine in
You put the mezzanine out
You put the mezzanine in
And you shake it all about...

And if you call it a 'storage platform' and don't have a spiral staircase, but use a mobile ladder to get up there...it's ok!
In the curious world of building rules and regulations, it is somehow safer to have a ladder, not attached to anything, than a fixed spiral staircase to provide access to the platform in the living room. Ours is not to reason 'why', apparently.
So the mezzanine storage platform is back in, but without the staircase.
Still in the world of strangeness, Council advised that the proposed zinc cladding (which would be on the exterior of the bay windows outside the bathroom, bedroom and Viktoria's studio) would be too reflective in the silver zinc colour. Given that where the house is located, the only thing it would be reflecting into would be the eyes of a passing pademelon, we were touched at Council's concern.
So we have had to change the material from zinc to Colorbond. We are using one of their new Metallics range, called Citi.
Here is a picture of some of the Colorbond Metallics. Citi is the one that takes up most of the photo. Good thing it's not silver.
In other news, the various specialists (engineers, hydronics, wastewater, fire management etc) have all provided their reports and/or drawings. These are now with Michael Lane from Cordwell Lane (our builder) for final costing. We have a couple of cheaper options up our proverbial sleeves if the costings come back at heart attack inducing levels - this may happen because since we last had an estimate from Michael, we have had to move the house further down the hill so that our driveway can accommodate the turning circle of an 8m long fire truck. Thank you new bush fire regs.
This will impact the cost increase in two ways:
  1. the driveway is going to cost a lot more because there is more of it, and it requires more fill, more engineering and a gabion rock wall to hold it all in place, and
  2. moving the house has meant that it is now on a steeper part of the land, which means that our 'slab on ground' is now partially suspended, which means more expensive footings and more brickwork
We are hoping to have the costings next week.
Until then, yours in anticipation
V&A

Monday, 6 January 2014

Our current home is now for sale...

We finally got our collective, dithering selves together, and our house is now listed on the market. It was actually a very sad thing, talking to the agent about what made us move there originally (nearly 9 years ago now),
But after a few epic cleaning sessions (did we mention that the walk-in wardrobe of our current home is 3 x 3 metres square?), and some professional photographs, it is listed for sale. Because the listing won't be around forever, here is a ridiculous amount of photos for posterity - as clean and tidy as it will ever be!
View from the street
Bottom deck, off the dining room
Bottom deck, from outdoor dining to outdoor living
From piano through to dining room
From piano through to living room
From living room back to piano
Kitchen
Top deck off master bedroom
Master bedroom
Another shot showing how large the master bedroom is
Upstairs bathroom with genuine Talavera tiles
Actual BATH in upstairs bathroom
2nd of three other bedrooms
Crazy wallpapered downstairs bathroom
View from the bottom deck - Morning fog in the valley with ocean
Some friendly locals
Sigh.
We will enjoy it while we are still living there.
It is a beautiful place to live.
And we will miss it.
V&A






Saturday, 4 January 2014

No more stair-book-case....No more mezzanine

As intimated in a previous post, we have lost the mezzanine and, as a consequence, AD's beautiful stair-book-case.
Beautiful stairbookcase and mezzanine will never be built
And here is why:
Firstly, the Building Surveyor determined that the mezzanine area, due to its restricted height from the raked ceiling, could not be defined as a 'habitable room'. Instead, it woul have to be known as an infrequently used 'service platform'. Well, that was ok, because it meant that the stairs which went inside AD's bookcase only needed to meet the reduced requirements for staircase design under Australian Standard 1657-1992. The Standard is less stringent than the Building Code in terms of height of step riser and width of step.
Sprial stairs inside the stairbookcase
This seemed like all very good news, because we wanted to keep the width of the stairs to the minimum because a) the mezzanine was only 1.8 metres wide; b) the living room itself is only 5 metres wide and c) anything too wide would destroy the pod design of the bookcase.
The Housing Industry of Australia (HIA) has this to say on staircase construction:
"If the proposed design has a stairway to a non-habitable room, then you may choose to design the stairs in accordance with this Part, or alternatively with AS 1657. The use of AS 1657 is ideal if there is limited space and/or the room will not be regularly used. This Standard allows a steeper stair to be built and is usually used to design access stairs for maintenance areas on buildings. In many ways the stair built to AS 1657 could be considered to be a step ladder with handrails."
A step ladder with handrails! Perfect!!
But because we had to provide the measurements of risers, goings and tread width as proof that the spiral stair design complied with AS 1657, we read the Standard.
And here was the second step in the demise of our stairbookcase.
  • s4.1 WIDTH AND ANGLE OF SLOPE Stairways shall not be less than 600mm wide measured between the inside edges of the handrails.
  • s4.2.3 CURVED STAIRWAYS The radius to the centreline of the stairway shall not be less than 600mm. Where the radius to the centreline of the stairway is less than 3000mm, the maximum width of the curved stairway shall be 750mm
Diagram showing minimum dimentions for curved stairways
AS 1657 makes absolutely no bloody sense. We are reasonably intelligent people, but interpreting the text with reference to the diagram ... well, how can there be a minimum 1200mm wide stair (radius) if the maximum permitted is 750mm? The maximum & minimum figures are mutually exclusive.
Further the MINIMUM distance form the centre pole to the 'imaginary centre line' of the step has to be 600mm, that would mean that the shortest radius you would be allowed to have would be 1200mm (or a spiral with a total diameter of 2400mm)!
2400mm is more than half the width of our living room, and seemed a little extravagant for something that is meant for access to an uninhabitable platform.
So we sought clarification from the Building Surveyor. He stated that he also interpreted the Standard as meaning a minimum of 1200 wide step treads.
He then capitulated and said that he "would be happy with the stair being 800mm radius internally" and that "although the BCA recognises this standard as a suitable design standard for non-habitable areas such as attics and storerooms and other such infrequently accessed areas – in this instance we must consider the likelihood of this stair being used by young children and the elderly".
We asked Nigel (Building Surveyor) whether, as his 'preferred' tread width of 800mm was also longer than the Standard stipulated maxiumum 750mm, would he be happy with a radius of 600mm? Noting that it says earlier at section 4.1 that “stairways shall be not less than 600mm wide”?
And here we enter phase three of the death of the mezzanine and the stairbookcase.
Essentially, irrespective of what it states in the BCA or the AS, unless the Building Surveyor is 'comfortable' with what you are doing, it's just not going to happen.
Nigel's response:
"600mm is very narrow and will affect the ability to achieve a good rise and go dimension and turn the stair so as the upper portion does not become a head clearance issue. It would also make it very difficult to carry any furniture, equipment or fittings safely up the stair. I think 750mm would be the bare minimum as this also reflects the minimum clear width of doorways in the Commercial BCA; maybe 720 at a push, which was previously an accepted width for toilet / pantry doors. I am not permitted to sign off a design that suits the current user, but must also consider future users of the house; ie. if you sell, unexpected arrivals, looking after elderly or disabled relatives, etc. – the BCA designs for a minimum 100 year durability of the overall building."
ADs design was based on the 600mm minimum stipulated in the standard (ie a 1200mm diameter).
Nigel would only approved a spiral stair with a 1500mm diameter.
1500mm would simply not be workable because a) the mezzanine was only 1.8 metres wide; b) the living room itself is only 5 metres wide and c) anything too wide would destroy the pod design of the bookcase.
Reluctantly, we had to advise the architects to focus their energy on something else, and we would have to lose the mezzanine (sorry the "service platform requiring access of epic proportions"), and its troublesome staircase.
Viktoria is particularly unhappy, as she has already lost the revolving bookcase from the original design, and has now lost the spiral staircase too.
If there is a silver lining, its that we are still going to have AD design us a bookcase based on the pod design, but this time it will be movable furniture and therefore not subject to the comfort level of the Building Surveyor.
And if he ever asks how we intend to get our books down from the top of the case, we'll tell him this:
V&A

Thursday, 2 January 2014

Random Thoughts for the New Year

It has been more than 20 years since 1,700 senior scientists (including 104 Nobel Prize winners) signed a document called 1992 World Scientist's Warning to Humanity.
 
It opens with the words:
"Human beings and the natural world are on a collision course. Human activities inflict harsh and often irreversible damage on the environment and on critical resources. If not checked, many of our current practices put at serious risk the future that we wish for human society and the plant and animal kingdoms, and may so alter the living world that it will be unable to sustain life in the manner that we know. Fundamental changes are urgent if we are to avoid the collision our present course will bring about""
 
Where will 2014 lead us?
V&A  

Monday, 23 December 2013

Some of the light fittings...

We are trying to get as many products sourced locally in Tasmania as we can. Some, however, we will have to get shipped from the mainland or from overseas.
Following on from the two day workshop at the JAWS Architects Office, these are the light fittings we can confirm will be going into the house, and which we know we can get from a local lighting supplier Casa Monde:
In the bathroom...the light fittings for the basins couldn't be obtained by Casa Monde, but we could get the heater:

IXL Tastic Neo Heater Exhaust in Silver
 Then in the Living Room areas we have:
Brilliant Galaxy 54" Timber Fan in Antique Bronze with timber blades
There is also a lot of LED strip lighting throughout the house, particularly in the Living & Kitchen.
In Viktoria's Studio, the main light is:
Emac & Lawton Brassiere Overhead Lamp in Rust
 And in her window-seat, reading area there will be a small wall lamp:
Emac & Lawton Seattle Spot Light in Antique Silver
 For the main bedroom, there is again some feature LED strip lighting, as well as a wall reading light:
Emac & Lawton Lincoln wall sconce in Antique Silver
 And to circulate hot air downwards, or to cool us on those rare balmy nights, there is also a ceiling fan in the bedroom:
Hunter Pacific Aurora II in burnt copper (not pictured) with black blades
And so we can see what the cats are up to at night time, in the cat garden there is some low wall lighting:


Oriel Lighting Konis Tex LED wall light in Graphite
 All down the concrete hallway, we have these wall lights (Australian made too!):

Robert Kitto Magill wall light in antique bronze
And the final (confirmed) fittings are the exterior sensor flood lights (which look like they actually come with laser weaponry...)
Crompton Lighting LED Sensor Floodlight
We did have a front door light picked out, but Viktoria has decided that most entry lights (that operate on sensors) are fairly uninspiring and/or ugly. So we may have to go down the route of picking out an exterior light we like, then rigging it to a separate sensor (which we were trying to avoid).
Sadly, we have been having a few dramas with the access stairs to the mezzanine... it has been a very frustrating & drawn out process, thus deserving of its own entry... but at the moment it's been a bit too exhausting to put on page.
Suffice to say, the end result is that it looks like we have lost our mezzanine, because the Building Surveyor would not sign off of the access stairs (unless we were to make them a completely unmanageable size for the dimensions of the room). But more on that later.
And more also on the rest of the fixtures we have agreed too... and soon some drawings from the architects showing some of the interior details.
Early 2014... we should begin to build....
V&A

Thursday, 5 December 2013

Choosing house fixtures & fittings... and lots to do

Who's been really really slack at updating their blog? Could it be us???
Things are still going along, with hopes to have the Building Application submitted before Christmas.
Building Surveyor, Nigel Grice, managed to get some sort of commitment from the local Council that we would not be held responsible for upgrading the access road. We're sure he thought we were quite batty persisting with this as we did, but it's hard to shake off that mainland paranoia that comes from dealing with regulatory & legal bodies every day (as Viktoria currently does).
Council have confirmed (in writing) that the road leading to our property is a “Council formed Road”; therefore in accordance with the Building Code of Australia it would not be considered a “private access road” and there is no obligation for us to upgrade it to meet the requirements of the Bushfire Management Plan.
In addition, Viktoria has recently returned from (yet another) lightning trip to Tasmania, where two days work shopping the fixtures, fittings & electrical layout were spent at the JAWS offices. Contrary to popular opinion, this was actually quite stress-free and fun (for Viktoria, at least, though she may have left a few architects twitching at the mention of her name). 
A lengthy wish list has been left with a local Tasmanian lighting supplier, Peter at Casa Monde. We would like to use Tasmanian companies as much as possible, but there are a few...ummm... odd items on the list which he may not be able to source. Once we have it firmed up, we'll post some pictures of some of our "star performers". Hopefully we won't have to shop anywhere else.
Viktoria also has a bit of drawing to do, as we are hoping to integrate a "disintegrating" pattern into part of the block work (based quite ludicrously on a ceramics exhibit... but we're sure it can work on a [much] larger scale... with completely different materials... anyway, Neal-the-Architect build a scale model and it worked there).
In the meantime, all the hard and technical work around plumbing, structure, power, etc have been left with Neal-the-Architect and Catherine-the-Architect.